ZDF221 d/w HEAT PRTOBLEM

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #58617
    servbland
    Participant

    We have recently been out to this Zanussi machine with a ” no heat ” fault . Heater , wiring , heat switch all tested o.k. We replaced pcb board which is the common problem with Zaussi d/ws , but after fitting new pcb board , we still have no heat . Can anyone help us with this one please ❓

    #335111
    bigchrisoioi
    Participant

    Re: ZDF221 d/w HEAT PRTOBLEM

    broken cable in bottom of door as it enters tub?

    #335112
    servbland
    Participant

    Re: ZDF221 d/w HEAT PRTOBLEM

    No , we have checked the wiring and all is ok . We have a circuit through the heat switch up to the board . We checked these things before ordering and fitting a new board which commonly is the cause of “no heat ” probs on dishwashers but this one has caught us out .

    #335113
    gandh1
    Participant

    Re: ZDF221 d/w HEAT PRTOBLEM

    have you run it on a diagnostic test run ? poor terminal connection when replaced the pcb – ie did you nip each terminal back on, they are notorious for opening out slighly when removing them…

    other than that dispensor solenoid failure… is it opening after first prewash???

    #335114
    servbland
    Participant

    Re: ZDF221 d/w HEAT PRTOBLEM

    Do you have the diagnostics procedure for this m/c ? Thanks ,by the way for the other ideas . As I am only the messenger , I will pass them on later and see where we go

    #335115
    servbland
    Participant

    Re: ZDF221 d/w HEAT PRTOBLEM

    😀 We have now successfully completed the repair , broken wire to temperature sensor , a pig to find as Bob had already metered it and had continuity . It was only when disconnected and pulled that the break became apparent . well done and thanks to bigchrisoioi !!!