Amica AWCT10L – polarity reversed

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Amica AWCT10L – polarity reversed

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #58875
    odom
    Participant

    Hi,

    Went to a job the other week – Amica with melted plug. Tested supply and polarity to entire flat had been reversed, e.g. live to neutral, neutral to live.

    Got them to call in a sparky before I went any further.

    Went back today, supply is now okay but machine won’t switch on. 230V to PCB so I assume suppressor is all right but PCB knackered – is there anything else on the machines that tend to get damaged with reversed polarity?

    I’ve tested the usual suspects with megger – heater, motor, door lock, but to be honest first time I’ve ever been to a job like this so not sure what else to expect – don’t want to blow a new PCB!

    Thanks in advance for your help!

    #335978
    kwatt
    Keymaster

    Thankfully, we don’t get too many that people the reverse the polarity on. In fact, not a one. 😉

    So, no idea.

    The customer does know that it won’t be covered by warranty don’t they?

    K.

    #335979
    odom
    Participant

    kwatt wrote:Thankfully, we don’t get too many that people the reverse the polarity on. In fact, not a one. 😉

    So, no idea.

    The customer does know that it won’t be covered by warranty don’t they?

    K.

    The whole flat had reversed polarity! Thought it must be a fault with my tester plug at first 😆

    Landlord is paying and they are none-too-pleased, but to be honest serves them right for hiring such a shoddy electrician in the first place.

Viewing 3 posts - 1 through 3 (of 3 total)