    Trips power after about a minute.

    had heater outer seems nothing wrong with it.

    On top of drum are 2 carbon pieces and the centre bit that holds them together is rubbing on drum and making quite a raket. In fact it tripped when the drum started to reverse.

    Is it possible that the carbon bits being worn is the problem.
    I dont understand what they are there for . Someone said its todo with the heat sense in the drum.

    Any help please.

    Mike

    #337340
    Seamy
    Participant

    Re: Miele T650C Tumble Dryer

    They are the automatic sensors of the dryer, if you look carefully you will notice that the drum is electrically insulated from the paddles, a resistance measurement is taken & electronics switch heater according to programme selected. Sensing is low voltage so shouldn’t trip a tripswitch if that’s what you mean. More likely to be motor, or heater fault.

    #337341
    washermanuk
    Participant

    Re: Miele T650C Tumble Dryer

    condensor dryer check lower base fan for condensation very common in making these trip out! the fan onlt comes on after a few mins? either dry this out or replace if too far gone? check condensor box seals as this lets steam get onto this fan moter! hope this helps?
    Brian 😉

    #337342
    mike100
    Participant

    Re: Miele T650C Tumble Dryer

    Thanks guys, will check out.

    Mike