beko drcs68 dryer

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #59285
    philfish
    Participant

    Any help appreciated.

    Got this dryer when its first started that day it starts as normal runs for about 10min with no heat at all then beeps clean filter and empty water container flash to say its finished. Then you switch it back on and it works perfect heats up, tumbles both ways, pumps out, dryers clothes perfect etc etc. Does not matter how many times you try it it will work perfect from then on in leave it overnight and then it goes through same sequence again.

    I’ve metered/meggared the element motor etc all perfect. ntc/senser meters ok rises/decreases with heat/cooling etc.

    Tried a 2nd hand board i had knocking about still exactly the same fault. I know i can’t trust a 2nd hand board but if it showed up a different fault at least then i would have a good idea it was the board but it was still the same.

    Perhaps i can’t see the wood for the trees on this one but i can’t find the problem and once it’s switched off then back on will work perfect and everything meters great so makes it even more difficult.

    Is it the pcb/board? stat/sensor?

    Thank you.

    Phil

    #337567
    helo_75
    Participant

    is it in an outhouse/ garage/ cold room

    sounds like ambient temperature lock out to me

    but if its indoors, its the front ntc thats at fault

    #337568
    philfish
    Participant

    Re: beko drcs68 dryer

    Thanks for that and the quick reply.
    Its inside so i will order the front ntc i metered that out but i am willing to try anything.

    Once again thank you.

    Phil