New Bosch wtv74306 is sporadicly F09ing-not get warm enuff?

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries New Bosch wtv74306 is sporadicly F09ing-not get warm enuff?

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #59530
    gandh1
    Participant

    put the siemens cousin in last week, tested on a 40 min timed cycled and it got hot in notime in the drum, tested this out on delivery and seemed only luke warm. low heat wasnt activated…

    tested it on senseor dry cupboard dry function with one damp towel and it got a f09 error.

    not got error since as far as i know.

    any info available would be great as due back this week to put a vent cover on outside wall!

    ta

    Rich

    #338561
    gandh1
    Participant

    Re: New Bosch wtv74306 is sporadicly F09ing-not get warm enu

    been informed this w/e its been F09’ing again.

    dont wanna get bosch round until i know what f09 is in case its a user caused error and they charge them…

    any advice?!?

    #338562
    BSH-MAN
    Participant

    Re: New Bosch wtv74306 is sporadicly F09ing-not get warm enu

    F9 = heater/NTC fault (no temp rise) unless the room temp is <-12C then it sounds like a fault.
    🙁

    #338563
    gandh1
    Participant

    Re: New Bosch wtv74306 is sporadicly F09ing-not get warm enu

    ahhhhh explains it

    it is in a external washroom, there is a boiler in there which keeps the chill off the room, but its not exactly toasty. plus machine had been kept outside in loading bay prior to installation.

    so will this be another one of those, start it up a couple of times before it works kinda situation till the artic weather passes?

Viewing 4 posts - 1 through 4 (of 4 total)