    I’m getting an E3 fault on the above D/W. This seems to be a heater/stat fault. I’ve tested the heater and thats ok. It has two stats, will I need to change both? Or could someting else be causing the fault?

    #339447
    Jackal
    Participant

    Re: Baumatic BDW13

    According to the service manual, Error E3 is a faulty pressure switch or system.

    My engineers advise it is common for the pressure system to gunk up which causes the unit to heat too quickly and trigger the E3 fault. I would check the pressure system first to be sure, but yes otherwise, change both the safety stat and the thermostat.

    PM me if you need the Service Manual.

    Regards

    Jackal

    #339448
    atech
    Participant

    Re: Baumatic BDW13

    Thanks for the advise. I will check the pressure switch/system. HAPPY NEW YEAR 😀