C6 reset on AEG 86741

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #59783
    scots
    Participant

    Hi Anyone know how to reset an AEG 86741 PNC 91400256200.
    Suspect caused by frozen pipes but cannot get the code cleared?

    Did have the TDS 2008 disc but it will not work now??


    Thanks Brian

    #339600
    Seamy
    Participant

    Re: C6 reset on AEG 86741

    C6 is pressure switch related.
    Think you hold in the Pre-Wash & Sensitive buttons while turning knob to Energy Save position, this brings you into Service Program. Turning knob to Cottons/Linen/Easy Cares while in service mode will clear faults.

    #339601
    scots
    Participant

    Re: C6 reset on AEG 86741

    Thanks for the info Seamy.

    Machine now repaired, after eliminating all other possibilitys I bit the bullet a went for the board. EMW did there magic and now working a treat.

    Just thought I’d let you know, maybe help someone else

    Brian

Viewing 3 posts - 1 through 3 (of 3 total)