Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Hotpoint wm73 no fill
- This topic has 6 replies, 2 voices, and was last updated 21 years, 8 months ago by
cornwell40.
-
AuthorPosts
-
August 9, 2004 at 6:11 pm #5996
cornwell40
ParticipantGood evening gents,
Been to one of these the elliptical lcd screen type, and have a fault of no initial fill. It will do a dry tumble for about about two minutes then bring water in. I’ve tested the heater and it’s down to earth. Just wondering if this could cause the fault. Another thing I’ve noticed is that the pressure switch only has one level, which makes contact once filled. Should this be a changeover switch as the other connection neither makes or breaks.
Any help appreciated. This is one of the “why do customers……..after a bearing change and new pump I’m testing the machine, notice said fault and customer says “Oh, I forgot to mention that!!” 😯
Tony CAugust 9, 2004 at 6:45 pm #115030Martin
ParticipantRe: Hotpoint wm73 no fill
Tony,
No doubt in saying the duff element is the problem and can and does affect the whole programme.
Change it and it should be sorted 😉 Check the state of the drum bearings though as it may have clobbered the element to caused the fault in the first place 💡
Martin
August 25, 2004 at 7:44 am #115031cornwell40
ParticipantRe: Hotpoint wm73 no fill
Martin on the ball as usual.
Heater causing the no fill problem, now changed and working fine 😀Thanks
Tony C.August 27, 2004 at 6:26 pm #115032cornwell40
ParticipantRe: Hotpoint wm73 no fill
Bl***y Hell 👿 👿 👿
This one has been sent to haunt me.
Fitted the heater a week ago all fine!!
Get a recall today , machine noisy. Huh?
Fitted bearings and spider last week and now the ali bearing collar is loose inside the foam outer.
In fifteen years and hundreds, of Hotpoint calls I’ve never seen this one before 👿
AND a pulley spoke busted getting the nut off………….
🙁 Tony C 🙁August 28, 2004 at 7:41 am #115033Martin
ParticipantRe: Hotpoint wm73 no fill
cornwell40 wrote:In fifteen years and hundreds, of Hotpoint calls I’ve never seen this one before 👿
Don’t think I have either Tony, was it a write off then or did you fit a new outer drum?
Martin
August 28, 2004 at 12:47 pm #115034cornwell40
ParticipantRe: Hotpoint wm73 no fill
I’ve got a few old tubs that I use for recons. A bit of time wasted but
its a fault I don’t think I’ll ever see again and the customer is ok with it.
She even noticed my sunned expression and made me another brew!!!!Tony C
August 28, 2004 at 2:24 pm #115035cornwell40
ParticipantRe: Hotpoint wm73 no fill
😳
That should read “stunned expression”
Tony C -
AuthorPosts
- You must be logged in to reply to this topic.