Hoover Quattro AE130

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #5999
    AMS
    Participant

    Has anyone come across this one before? Hoover Quattro Easylogic AE130 (the one with the display). Program starts as normal but aborts after about 10 minutes with 3 bars on the display. Customer turns machine off at the wall for 20 – 30 minutes, then turns it back on again, and the program resumes and continues happily until the end. I’ve not been to it yet, but I’m hoping that someone out there knows exactly what it is and can save some me some time and effort.

    Many thanks

    #115045
    Martin
    Participant

    Re: Hoover Quattro AE130

    AMS,

    Power interruption I reckon 😉

    Possibly the door lever not holding the microswitch/interlock? 13amp plug connection dodgy?…..something like that most likely.

    Martin

Viewing 2 posts - 1 through 2 (of 2 total)