    Hi guys we have been called out too this dwasher which was flooding. we found the small hose off circ pump was split. this hose only comes complete with circ pump which we have replaced but now we have a fault where after the first fill the machine decides too pump out and then the alarm goes off and the indicator light flashes 5 times!we have checked the forum and checked everything that it sais it might be but no joy! any ideas would be a great help thanks

    #342037
    whiskey_six
    Participant

    Re: diplomat/whirlpool dwasher

    had the same last week. found that water had gone onto the ntc and had shorted out. The other thing to check is that the diagphram is free in the pressure chamber and is not stuck. The ntc pushes into the sump to the left of the heater and the pressure chamber is in a similar position.

    #342038
    loopey
    Participant

    Re: diplomat/whirlpool dwasher

    5045173408166 Coupling service kit 🙂 £10

    #342039
    spuzzer
    Participant

    Re: diplomat/whirlpool dwasher

    had the same last week. found that water had gone onto the ntc and had shorted out. The other thing to check is that the diagphram is free in the pressure chamber and is not stuck. The ntc pushes into the sump to the left of the heater and the pressure chamber is in a similar position.[/quote thanks very much whiskey -six will check that

    #342040
    spuzzer
    Participant

    Re: diplomat/whirlpool dwasher

    loopey wrote:5045173408166 Coupling service kit 🙂 £10

    great thanks loopey will try that