  • #60559
    scoobya1
    Participant

    THIS MACHINE WAS REPORTED AS CUTTING OUT BEFORE COMPLETING THE DRYING. DRAGGED INTO WORKSHOP AS TOO COLD TO WORK ON IN BARN! TESTED AND FOUND NO FAULT. RETURNED TO HAVE SAME FAULT REPORTED. REPLACED TEMP LIMITER 600157. CUSTOMER REPORTED FIRST DRY WAS FINE BUT SINCE IT IS CUTTING OUT EARLY AGAIN. OH, AND NOW LEAKING! ANY CLUES PLEASE?

    #342688
    Martin
    Participant

    Re: BOSCH WTE84103GB/05

    Please don’t shout. 🙂

    (Turn your caps lock off please?):wink:

    Most likely the “barn” is too cold an environment and the NTC cannot function. Tumble dryers using electronics and NTC’s cannot function in outbuildings subjected to extreme low ambient temperatures.

    Leaking?…. Pump to tank hose blocked, safety float operated, condenser door seal? etc…

    HTH?:D

    #342689
    scoobya1
    Participant

    Re: BOSCH WTE84103GB/05

    Sorry! Bad day – need anger management!! Or open a shoe shop!!
    Did think maybe the external temp could be a prob, which I guess is proved as it worked in the workshop – mind you it’s not much warmer in here!!!