Whirlpool AWOD6727 no pump?

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #60618
    iadom
    Moderator

    12nc.8592 969 15007

    Customer has already fitted a new pump to no avail. both the new and old pump check out perfectly.

    No blockages whatsoever, pump just doesn’t run.

    Tested between to two black wire terminals on the PCB to the pump and have a good circuit, apart from the PCB itself is there anything else that can cause this?

    Jim.

    #342947
    johnmac11
    Participant

    Re: Whirlpool AWOD6727 no pump?

    I’ve seen this before Jim, check the voltage to the pump when energised, if the timer is dodgy it will be well below 230v. I have had some with70v at the pump and the timer caused the problem.


    John

    #342948
    iadom
    Moderator

    Re: Whirlpool AWOD6727 no pump?

    Hi John, by timer I assume you mean the main control PCB?

    Jim.

    #342949
    johnmac11
    Participant

    Re: Whirlpool AWOD6727 no pump?

    Yes the PCB, as far as I am concerned anything which controls a machine should be called a timer, wasn’t life simpler in the old days when all you had to do was get the right crouzet timer for the machine 😀

    John

    #342950
    chezza
    Participant

    Re: Whirlpool AWOD6727 no pump?

    Ah , timers …… dozens of individual wires , always 1 left hanging loose after fitting a new one ,,,,,, those were the days 😆

    you have mail, jim

    #342951
    iadom
    Moderator

    Re: Whirlpool AWOD6727 no pump?

    Thanks guys, 8)

    Jim.