Aeg Washer Dryer, L12700VIT Prd 914601902

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Aeg Washer Dryer, L12700VIT Prd 914601902

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #60763
    ray.t
    Participant

    Been to this today customer complained of no heat on dry.
    Checked through heater and cut outs etc and all seems fine. I checked for power to the heater and there is no neutral to the element.
    The machine brings up no fault codes and appears to work as normal all the way through the cycle but just no heat.
    Thanks,
    Ray

    #343530
    Seamy
    Participant

    Re: Aeg Washer Dryer, L12700VIT Prd 914601902

    You need to be checking the cut-outs with the cables disconnected. Theres circuit diagrams on TDS

    #343531

    Re: Aeg Washer Dryer, L12700VIT Prd 914601902

    If it’s same as late Zanussi, check integrity of thin orange wires connected to thermistor in condenser to tub hose down on the right.
    Mike.

    #343532
    ray.t
    Participant

    Re: Aeg Washer Dryer, L12700VIT Prd 914601902

    Thanks for the advice on this, I am never going to find out as the owners are going to buy new.
    Cheers,
    Ray

    #343533
    Specialist01269
    Participant

    Re: Aeg Washer Dryer, L12700VIT Prd 914601902

    You could allways offer them a Fiver for it for bits, then at least you’d know.

Viewing 5 posts - 1 through 5 (of 5 total)