homeking dw hi model no is hl13 so im told,need ntc and elem Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › homeking dw hi model no is hl13 so im told,need ntc and elem This topic has 2 replies, 2 voices, and was last updated 15 years, 1 month ago by eng14. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts February 15, 2011 at 8:00 pm #61076 eng14Participant hallo this homeking hl13 dw needs ntc and element please richard. 😕 February 15, 2011 at 9:10 pm #344749 bazza500Participant Re: homeking dw hi model no is hl13 so im told,need ntc and temperature sensing device X672050280017 protecting thermostat X672050280013 heating element X672050310019 March 1, 2011 at 8:00 am #344750 eng14Participant Re: homeking dw hi model no is hl13 so im told,need ntc and element had gone,but changed all 3 parts.still coming up e3 in cycle,richard. Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In