Belling IDW604 d/w

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #61512
    dave-m
    Participant

    Hi all,
    Does anyone have a service manual for this machine, I’m trying to find out why I can’t get it to send any power to the element on the back of an e3 fault.

    Regards

    DM

    #346454
    Seamy
    Participant

    Re: Belling IDW604 d/w

    Some of then, depending on who made it will have a switch in series with the heater, it needs water pressure to activate the switch & the heater. Low water level, poor pump pressure, blocked filters can cause it not to heat & bring E3 fault.
    Dimpco should be able to get you the required tech’ info i’d expect.

    #346455
    dave-m
    Participant

    Re: Belling IDW604 d/w

    Thanks for that seamy, Going back later for another look later….

    #346456
    dave-m
    Participant

    Re: Belling IDW604 d/w

    anyone know how much resistance i should be getting across the thermistor on this.