Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › bosch wvd24520gb
- This topic has 16 replies, 4 voices, and was last updated 15 years ago by
deltra.
-
AuthorPosts
-
March 14, 2011 at 10:13 pm #61657
deltra
Participanthi all, this dryer does heat up but the clothes are still wet when the timer ends. steam comes out of soap draw. fitted a new valve(triple) for e17 fault code, dryer hasnt worked properly since ❗ it does allow a little amount of water in to condenser at start of drying cycle,then stops and no more water intake(during drying,wash ok) any ideas or a manual would be much appreciated 😀
March 15, 2011 at 2:10 am #347076gandh1
ParticipantRe: bosch wvd24520gb
solenoid wired up ok??? hoses on the right nipples?
March 15, 2011 at 8:26 am #347077Martin
ParticipantRe: bosch wvd24520gb
The usually come up with an F17 error code not E17, so that’s a bit odd. 😕
F17 is normally associated with a water inlet flow problem and being as you’ve changed the valve already you will need to check the water flow through the condenser. Not an easy access by any means, but could well be the condenser is blocked with fluff.
March 15, 2011 at 10:19 pm #347078deltra
ParticipantRe: bosch wvd24520gb
hi, water does flow into condenser, at start of cycle, then no flow after that initial flow ❓ no more fault codes come up,your right it was f17.
March 15, 2011 at 10:27 pm #347079leavemetogetonwithit
ParticipantRe: bosch wvd24520gb
Maybe it’s throwing an “Electrolux” = valve coil going open when it warms up.
Mike.March 15, 2011 at 11:50 pm #347080gandh1
ParticipantRe: bosch wvd24520gb
but surely unlikely if its a new valve though?? put it on a rinse only and see how much it fills the tub, its very easy to get the hoses mixed up with the triple coils, unless im just stupid 🙂
March 16, 2011 at 12:05 am #347081leavemetogetonwithit
ParticipantRe: bosch wvd24520gb
gandh1 wrote: its very easy to get the hoses mixed up with the triple coils
That sounds possible. Could even be someone had a go before you got there, and customer neglected to mention it :rolls: .
Mike.March 16, 2011 at 12:18 am #347082gandh1
ParticipantRe: bosch wvd24520gb
wheres paul when you need him?
March 16, 2011 at 3:58 pm #347083deltra
ParticipantRe: bosch wvd24520gb
anyone got a wiring diagram,maybe ive put wires on wrong!
March 25, 2011 at 12:51 pm #347084deltra
ParticipantRe: bosch wvd24520gb
been back to this again,fitted another triple valve! still same fault!!! sometimes the machine stops after 10 mins, even though timer was set to 2 hours! anyone got a manual please.
March 25, 2011 at 5:40 pm #347085leavemetogetonwithit
ParticipantRe: bosch wvd24520gb
Is there 240v across the relevant valve coil? Is it that that shuts down after 10 mins, or the flow of water before that? My stab in the dark guess would be that there’s some sort of flow restrictor getting blocked somewhere.
Mike.March 25, 2011 at 6:30 pm #347086Martin
ParticipantRe: bosch wvd24520gb
Are you still getting the F17 error code? Have you cleaned the condenser?
March 27, 2011 at 7:42 pm #347087deltra
ParticipantRe: bosch wvd24520gb
hi all,the f17 fault has been cleared,condenser is clear, no fault codes are coming up
March 28, 2011 at 2:41 pm #347088deltra
ParticipantRe: bosch wvd24520gb
fitted 3 valve this morning, now everything works a treat!
March 28, 2011 at 2:46 pm #347089Martin
ParticipantRe: bosch wvd24520gb
deltra wrote:fitted 3 valve this morning, now everything works a treat!
So the first new valve you fitted was duff was it?
-
AuthorPosts
- You must be logged in to reply to this topic.