bosch wvd24520gb

Viewing 15 posts - 1 through 15 (of 17 total)
  • Author
    Posts
  • #61657
    deltra
    Participant

    hi all, this dryer does heat up but the clothes are still wet when the timer ends. steam comes out of soap draw. fitted a new valve(triple) for e17 fault code, dryer hasnt worked properly since ❗ it does allow a little amount of water in to condenser at start of drying cycle,then stops and no more water intake(during drying,wash ok) any ideas or a manual would be much appreciated 😀

    #347076
    gandh1
    Participant

    Re: bosch wvd24520gb

    solenoid wired up ok??? hoses on the right nipples?

    #347077
    Martin
    Participant

    Re: bosch wvd24520gb

    The usually come up with an F17 error code not E17, so that’s a bit odd. 😕

    F17 is normally associated with a water inlet flow problem and being as you’ve changed the valve already you will need to check the water flow through the condenser. Not an easy access by any means, but could well be the condenser is blocked with fluff.

    #347078
    deltra
    Participant

    Re: bosch wvd24520gb

    hi, water does flow into condenser, at start of cycle, then no flow after that initial flow ❓ no more fault codes come up,your right it was f17.

    #347079

    Re: bosch wvd24520gb

    Maybe it’s throwing an “Electrolux” = valve coil going open when it warms up.
    Mike.

    #347080
    gandh1
    Participant

    Re: bosch wvd24520gb

    but surely unlikely if its a new valve though?? put it on a rinse only and see how much it fills the tub, its very easy to get the hoses mixed up with the triple coils, unless im just stupid 🙂

    #347081

    Re: bosch wvd24520gb

    gandh1 wrote: its very easy to get the hoses mixed up with the triple coils

    That sounds possible. Could even be someone had a go before you got there, and customer neglected to mention it :rolls: .
    Mike.

    #347082
    gandh1
    Participant

    Re: bosch wvd24520gb

    wheres paul when you need him?

    #347083
    deltra
    Participant

    Re: bosch wvd24520gb

    anyone got a wiring diagram,maybe ive put wires on wrong!

    #347084
    deltra
    Participant

    Re: bosch wvd24520gb

    been back to this again,fitted another triple valve! still same fault!!! sometimes the machine stops after 10 mins, even though timer was set to 2 hours! anyone got a manual please.

    #347085

    Re: bosch wvd24520gb

    Is there 240v across the relevant valve coil? Is it that that shuts down after 10 mins, or the flow of water before that? My stab in the dark guess would be that there’s some sort of flow restrictor getting blocked somewhere.
    Mike.

    #347086
    Martin
    Participant

    Re: bosch wvd24520gb

    Are you still getting the F17 error code? Have you cleaned the condenser?

    #347087
    deltra
    Participant

    Re: bosch wvd24520gb

    hi all,the f17 fault has been cleared,condenser is clear, no fault codes are coming up

    #347088
    deltra
    Participant

    Re: bosch wvd24520gb

    fitted 3 valve this morning, now everything works a treat!

    #347089
    Martin
    Participant

    Re: bosch wvd24520gb

    deltra wrote:fitted 3 valve this morning, now everything works a treat!

    So the first new valve you fitted was duff was it?

Viewing 15 posts - 1 through 15 (of 17 total)