hotpoint wd440 error f4

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #61697
    JENKS
    Participant

    called to this washer dryer last week with error f15(dryer heater relay),changed module from emw and that sorted the f15 fault but it then came up with error f4(pressure switch stuck on empty)pump running continuously.checked pressure switch seems ok,checked pipework for blockages seems ok.anyone else had simular problem.

    #347264
    aqualectric
    Participant

    Re: hotpoint wd440 error f4

    Remove the PCB and tighten all the edge connectors. Also get a new pressure switch – they burn internally for a passtime and at around £6 it’s a cheap fix. I’ve fitted quite a few of them…. 😉

    HTH,

    Steve.

Viewing 2 posts - 1 through 2 (of 2 total)