Siemens microwave

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #61792
    franz
    Participant

    either HB86K58B or HB 86K70B – have’nt been yet ,customer says when m/wave setting is used that the mw only runs for 2 secs then shuts down – any ideas what might cause this?
    Franz

    #347637
    PINKY
    Participant

    Re: Siemens microwave

    Internal fuse blown, Caused by magnetron and invertor faulty. Or door switch if your realy lucky

    Pink…

    #347638
    loopey
    Participant

    Re: Siemens microwave

    magnets cracked on magetron is my lucky guess 9 times out of ten is the usual 🙂

    #347639
    franz
    Participant

    Re: Siemens microwave

    Thanks for the pointers guys
    Franz

    #347640
    bosch-engineer
    Participant

    Re: Siemens microwave

    If it cuts out after 3 seconds & the 10a pcb fuse is open circuit it is the inverter. If you are very lucky & the 10a pcb fuse is ok, then it is probably the door switches. If it cuts out after 22 seconds, its the magnetron. In short, 3 secs – inverter. 22 secs- magnetron.

    #347641
    loopey
    Participant

    Re: Siemens microwave

    bosch-engineer wrote:If it cuts out after 3 seconds & the 10a pcb fuse is open circuit it is the inverter. If you are very lucky & the 10a pcb fuse is ok, then it is probably the door switches. If it cuts out after 22 seconds, its the magnetron. In short, 3 secs – inverter. 22 secs- magnetron.

    Great post bosch-engineer , i probs dont see as many as you , all ways been the magnetron in my case lol as well as door switches , In all the years the inverter systom has been out
    i have never had to change one suppoes ive all ways been lucky

Viewing 6 posts - 1 through 6 (of 6 total)