  • #61809
    Taff
    Participant

    This machine was not completing the full cycle. Test sequence was entered by holding the start pause and another button and turning the program knob one click to the right. On third position the pump runs for about twenty seconds, then an error code is emmitted. Five flashes of the LED with the arrow with one flash of, the start pause button. Does anybody know this error code, or a manual please? ❓ ❓

    Regards

    Taff

    #347686
    gandh1
    Participant

    Re: Zanussi TCE7227W Tumble Dryer

    e51 motor faulty, wiring from motor faulty, pcb faulty.

    have had this where the main plastic fan wears loose, therefore wobbles off center, and jams motor,

    or

    been overloaded, belts gone, and spring that tensions motor to jockey whl pings out, taking some of the loom with it

    or

    motors overheated and internal armature cooling impeller has melted, jamming motor…

    PLUG OUT FIRST, then remove RHS panel for access to motor/loom/belt/fans