hotpoint wml50

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #62012
    tash
    Participant

    hi all,been to two wml50 p ukr date code 80 washers with same fault this week,just thought it might be a common problem on this model,basically they leak on the front left side,although didnt when i tested them, i cleaned out disp inner and outer checked disp hose all usual stuff,reduced inlet pressure ,leveled out etc,holes in disp top seem clear but i know some can spray at a funny angle causing leak,anyway just a thought if anyone has any ideas,, dont think much to the design ..sealed tub,,,welded front panel,, not very repair friendly 😯 thanks

    #348398
    washtronics
    Participant

    Re: hotpoint wml50

    i used to work for hotpoint/indesit and yes it is a common fault that you will struggle to cure, they leak from the dispenser area, changing disp may cure for a while but it is the design-as you say not very repair friendly

    #348399
    tash
    Participant

    Re: hotpoint wml50

    hmm thought so..thanks for repl 🙁 y

    #348400
    jonnieboy
    Participant

    Re: hotpoint wml50

    if its the rotary type dispenser there is a modified dispenser out that cures the leak problem part no is
    COO281253
    fitted loads for nuisance leaks at dispenser and not had a problem well not with leaking from disp lol…. 😀

    #348401
    tash
    Participant

    Re: hotpoint wml50

    thanks for that info,,appreciated,, tash