Smeg DWF64 SSE Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Smeg DWF64 SSE This topic has 3 replies, 2 voices, and was last updated 14 years, 11 months ago by geoff1. Viewing 4 posts - 1 through 4 (of 4 total) Author Posts April 29, 2011 at 11:58 am #62499 geoff1Participant Hi Please could anyone help with information on this unit. The fault I have is that the drain pump will run for about 1 or 2 seconds, disply lights flash off then on again and that is it. Many thanks Geoff May 2, 2011 at 7:10 pm #350279 geoff1Participant Re: Smeg DWF64 SSE Bump Any Smeg experts out there ❓ Geoff May 2, 2011 at 7:49 pm #350280 eastlmarkModerator Re: Smeg DWF64 SSE any water inside (blocked, unable to dain the short fills at start up) or leaked into the drip tray? Check for any earth leakage on the circ pump or even pull the plug on the circ pump and see what happens. otherwise suspect PCB problem. May 3, 2011 at 6:28 pm #350281 geoff1Participant Re: Smeg DWF64 SSE Hi Thanks for reply will go back to look at earth leakage again as no water in pump and pump will run ok if float in base is activated Geoff Author Posts Viewing 4 posts - 1 through 4 (of 4 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In