Heatrae Sadia Water Boiler

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #6265
    Seamy
    Participant

    Anyone ever worked on a water boiler “Heatrae Sadia Supreme 140”? it fills to half full, indication shows 1/2 full, then fills to full, full indicator comes on, then the on indicator flashes repeatedly & no boiling? Element checks o.k as do level probes, anyone shed any light on this, i don’t see too many of these!

    Ta in advance,
    Seamy

    #116680
    tonyclifton
    Blocked

    Re: Heatrae Sadia Water Boiler

    try resetting the start- dry cut-out (green button) or the over-temperature cut out (red button) one of them usually does the trick if not replace them

Viewing 2 posts - 1 through 2 (of 2 total)