ParticipantAre their any error codes for these machines?Got one with a few lights on but nothing happening.
May 13, 2011 at 1:44 pm #351320Martin
ParticipantRe: Hotpoint Aqualtis
reaper wrote:Are their any error codes for these machines?
Sure there are, what’s the exact model number though, there’s dozens? 😕
May 14, 2011 at 4:11 pm #351321reaper
ParticipantRe: Hotpoint Aqualtis
AQ9L 291(UK)V. Its amazing how many different models this shower can produce in a short time and no doubt theres plenty of variation within each model number.
May 16, 2011 at 7:23 am #351322Martin
ParticipantRe: Hotpoint Aqualtis
reaper wrote:AQ9L 291(UK)V.
The error codes for this heap of junk are on Page 53 of the UKW Fault Code Bible…..Amen! 🙂
May 18, 2011 at 3:24 pm #351323reaper
ParticipantRe: Hotpoint Aqualtis
Eventually getting an error code on this machine.Start button flashing and the first row of lights have nos.2,4and 5 lit up ,I presume this is F10 fault -pressure switch fault.Pressure switch is a crappy blue thing with a small connector block and 5 connections(most hpts have 4).EMW have repaired and tested the pcb(Mk10 -the original fault was that the display was frozen on and wouldnt reset even when you unplugged the machine and plugged it in again)Now it fills and the error code flashes up but it will do the spin cycle ok except the pump doesnt kick in.(Pump and pump circuit ok).Why 5 connections on the p/switch, Im presuming that the pump not working is something to do with the p/switch(got one on order),circuit diag would be appreciated.
May 18, 2011 at 3:27 pm #351324iadom
ModeratorRe: Hotpoint Aqualtis
PM me your e-mail address and I will see what I have.
Jim.
May 21, 2011 at 10:26 am #351325reaper
ParticipantRe: Hotpoint Aqualtis
PM’d you with e-mail.
May 21, 2011 at 12:55 pm #351326iadom
ModeratorRe: Hotpoint Aqualtis
It was sent to the e-mail address you gave me on the 19th.
Let me know if it did not arrive and I will resend.
Jim.
May 22, 2011 at 8:56 am #351327johnnyj
ParticipantRe: Hotpoint Aqualtis
I’m sure if these dont sense water in them the pump wont run, they use a linear pressure switch, you have to watch when working on them if you tip them to far back it screws them upJJ
May 24, 2011 at 8:50 am #351328iadom
ModeratorRe: Hotpoint Aqualtis
reaper wrote:PM’d you with e-mail.
Something wrong with the e-mail address you gave me, I sent it on the 19th and it has just been bounced back today. 😕Jim.
-