Hotpoint Aqualtis

Viewing 10 posts - 1 through 10 (of 10 total)
  • Author
    Posts
  • #62789
    reaper
    Participant

    Are their any error codes for these machines?Got one with a few lights on but nothing happening.

    #351320
    Martin
    Participant

    Re: Hotpoint Aqualtis

    reaper wrote:Are their any error codes for these machines?

    Sure there are, what’s the exact model number though, there’s dozens? 😕

    #351321
    reaper
    Participant

    Re: Hotpoint Aqualtis

    AQ9L 291(UK)V. Its amazing how many different models this shower can produce in a short time and no doubt theres plenty of variation within each model number.

    #351322
    Martin
    Participant

    Re: Hotpoint Aqualtis

    reaper wrote:AQ9L 291(UK)V.

    The error codes for this heap of junk are on Page 53 of the UKW Fault Code Bible…..Amen! 🙂

    #351323
    reaper
    Participant

    Re: Hotpoint Aqualtis

    Eventually getting an error code on this machine.Start button flashing and the first row of lights have nos.2,4and 5 lit up ,I presume this is F10 fault -pressure switch fault.Pressure switch is a crappy blue thing with a small connector block and 5 connections(most hpts have 4).EMW have repaired and tested the pcb(Mk10 -the original fault was that the display was frozen on and wouldnt reset even when you unplugged the machine and plugged it in again)Now it fills and the error code flashes up but it will do the spin cycle ok except the pump doesnt kick in.(Pump and pump circuit ok).Why 5 connections on the p/switch, Im presuming that the pump not working is something to do with the p/switch(got one on order),circuit diag would be appreciated.

    #351324
    iadom
    Moderator

    Re: Hotpoint Aqualtis

    PM me your e-mail address and I will see what I have.

    Jim.

    #351325
    reaper
    Participant

    Re: Hotpoint Aqualtis

    PM’d you with e-mail.

    #351326
    iadom
    Moderator

    Re: Hotpoint Aqualtis

    It was sent to the e-mail address you gave me on the 19th.

    Let me know if it did not arrive and I will resend.

    Jim.

    #351327
    johnnyj
    Participant

    Re: Hotpoint Aqualtis

    I’m sure if these dont sense water in them the pump wont run, they use a linear pressure switch, you have to watch when working on them if you tip them to far back it screws them upJJ

    #351328
    iadom
    Moderator

    Re: Hotpoint Aqualtis

    reaper wrote:PM’d you with e-mail.


    Something wrong with the e-mail address you gave me, I sent it on the 19th and it has just been bounced back today. 😕

    Jim.

Viewing 10 posts - 1 through 10 (of 10 total)
  • You must be logged in to reply to this topic.