Bosch Enr- WAS28466GB08 W/m stuck on 1 min left

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Bosch Enr- WAS28466GB08 W/m stuck on 1 min left

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #63287
    nospin
    Participant

    Been to this twice. I ordered a new door lock and have fitted it as i have mostly found that with most machines, the lock doesn’t release and PCB stays with 1 min left.Only the quick wash cycle works and opens the door at the end???? Any help please???

    #353313
    odom
    Participant

    Re: Bosch Enr- WAS28466GB08 W/m stuck on 1 min left

    Have you checked heater element for insulation? Normally this causes it to stick on 1min.

    #353314
    nospin
    Participant

    Re: Bosch Enr- WAS28466GB08 W/m stuck on 1 min left

    Cheers Chris, sorry for not getting back to you. I never had the pleasure to find out as it was an insurance job. The customer made a fuss and had machine replaced. I now have a brand new element armed for next 1 min left fault. Thanks again