Hoover TV630-001 no power to the elements

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hoover TV630-001 no power to the elements

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #63369
    TELL
    Participant

    been to this m/c today, and i’m not getting 240v to the elements, test heater cut out stat on top, found i’m getting a circuit through it ok, went to the front duct stat found the same,ok. trace back through to the timer and found that i’m not getting 240v out on the red wire to the heater temp selector switch, but below that contact on the timer i take to be the feed (Live) in is the brown and white wire, with 240v there, has any body got a wiring diagram prod code 37616307.
    also the filter care light is on, ISit the timer? or have i missed something, there is no other thermal cut outs i can see on this appliance.
    thanks
    TELL..
    Ps, the element is ok, i’ve got readings on both elements.

    #353579
    timdowning
    Participant

    Re: Hoover TV630-001 no power to the elements

    The earlier heater assy’s had one stat on top of the heater assy & a one shot inline cut-out inside the heater assy.

    The later type ones had the one shot stat on the left & the normal operating stat on the right.

    Is your heater the early version?

    For test purposes only you can by-pass the hidden one shot inline cut-out.

    #353580
    TELL
    Participant

    Re: Hoover TV630-001 no power to the elements

    hi,timdowning
    mine must be the earlir one, has a single stat on top,but if its an internal one shot cut out, how is it that when i’ve disconnected the 3 wires to the element, red,yellow, and white, that i’m getting a reading through both elements. the stat on the top has 240v, and is still in circuit.