Hotpoint Freezer FZA84G – fan not running

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hotpoint Freezer FZA84G – fan not running

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #63372
    neon_3SP_glow
    Participant

    The machine runs the comp. and gets cold, but no fan action. the fan tested ok.

    Please can some one tell me what conditions cause the fan to not get a live feed?

    The de-frost thermal cut out seems to be open circuit.

    Would i be correct in assuming the fan is fed through this cut out?

    many thanks in advance.

    #353585
    spimps
    Participant

    Re: Hotpoint Freezer FZA84G – fan not running

    You can trace the fan supply via the connectors back to the control pcb.
    The fan is often controlled via the sensor and pcb which will switch the fan on when evaporator temp is -12c approx.
    Have in the past when desperate,providing it is an a/c fan connected the fan terminal with the compressor supply at the pcb so it comes on when the compressor runs.