    adv
    Participant

    hi this dw seems to fill an empty all time does switch off on appliance no lights on pcb to pick a programme no water in base am thinkin pcb help lads?

    #355039
    Martin
    Participant

    Re: siemans dw se64a630gb/17

    That would indicate the transfer tube and pressure chamber are gunged up. Have you checked to see if its clear?

    #355040
    adv
    Participant

    Re: siemans dw se64a630gb/17

    No lights on pcb to pic prog or reset it?

    #355041
    wizard
    Participant

    Re: siemans dw se64a630gb/17

    More than likely pcb, probably blown due to leak on flow diverter on heater. Wiz

    #355042
    adv
    Participant

    Re: siemans dw se64a630gb/17

    na point fitting new pcb en?

    #355043
    Martin
    Participant

    Re: siemans dw se64a630gb/17

    adv wrote:na point fitting new pcb en?

    Take the PCB apart, check which track is blown then you can trace direct to the component that caused it. Usually as Wiz says it’s the heater box diverter and on rarer occasions the dispenser solenoid can be a caution. The PCB will often tell it all. 😀