Hoover HCF5176W – R600a charge

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hoover HCF5176W – R600a charge

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #63958
    whiskey_six
    Participant

    Hi Folks,

    Just lost the will to live with Hoover tech support ( Wish Kev H had not retired )
    We have a 3 year old Hoover unit that needs a regas but the label has been removed.It doesn’t say the charge on the Giastech web site. Anyone know what charge goes into it. I have booked it for early next week so not really any rush.

    Cheers
    Mike

    #355642
    BobHope
    Participant

    Re: Hoover HCF5176W – R600a charge

    55grams sounds about right but it a while since i did one, just watch the backpressure on the gauge and depending on what scale is on the gauge set the evaporating temp to -32c. or -0.6 bar.

    Bob.

    #355643
    loopey
    Participant

    Re: Hoover HCF5176W – R600a charge

    yer whiskey_six kev retired lost a good un there 🙁 spot on bob 59 is the correct amount according to my records … 🙂

    #355644
    whiskey_six
    Participant

    Re: Hoover HCF5176W – R600a charge

    Thanks to both of you. The engineer just rang me and asked, I had forgotten about the job ( Old age creeping in at 46 haha ). Kev was the oracle of Gias, such a shame he chose to sun himself and spend his days relaxing.