Hotpoint ctd 80 p

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #64075
    knobs
    Participant

    Hi all,The empty water light keeps coming on,have checked resovoir,pump is working,no blockage in both pipes up to resovoir.evaporator clean. ideas ?
    thanks

    #355973
    Martin
    Participant

    Re: Hotpoint ctd 80 p

    I seem to recall there were some issues with the pump and float mechanism and a mod carried out?

    #355974
    knobs
    Participant

    Re: Hotpoint ctd 80 p

    ok thanks will have a look at the float,see if its gunged up

    #355975
    DDSDDS
    Participant

    Re: Hotpoint ctd 80 p

    is this the one with the pump impellor is a sort of strange elastic thing if so they come loose and the pump run but no water will be shifted

    #355976
    knobs
    Participant

    Re: Hotpoint ctd 80 p

    makes sense,will have a shufti
    cheers

Viewing 5 posts - 1 through 5 (of 5 total)
  • You must be logged in to reply to this topic.