ZWD16270WI Not Starting

Viewing 8 posts - 1 through 8 (of 8 total)
  • Author
    Posts
  • #64159
    pmb
    Participant

    ZWD16270WI 914604030.
    User had code E20,They cleaned filter, then not starting and no code appearing,
    Thought i found fault dodgy connection on dryer thermister on hose to condenser, had to soldier. Its still the same,
    If i put it on Wash or Spin it pumps for a few seconds then nothing but lights stay on.Door locks
    There is a small Board (PCB relay assembly) with relays that makes a strange noise when trying to start not sure if thats normal, Never noticed this board before.
    Any ideas 💡

    #356243
    Criscold
    Participant

    Re: ZWD16270WI Not Starting

    You may have to go into diagnostics to get correct code

    #356244
    timdowning
    Participant

    Re: ZWD16270WI Not Starting

    Did you electrically test the dryer element?

    #356245
    Martin
    Participant

    Re: ZWD16270WI Not Starting

    Sounds like Inverter board has got problems? Maybe they splashed a lot of water about sorting the filter…water v’s electric…ouch!

    #356246
    pmb
    Participant

    Re: ZWD16270WI Not Starting

    Disconnected Dryer heater= still faulty.
    Whats the inverter board, it it the one with the relays on
    Part number 1324478021

    #356247
    Criscold
    Participant

    Re: ZWD16270WI Not Starting

    No thats the dryer module, inverter board in base of machine

    #356248

    Re: ZWD16270WI Not Starting

    Could be insulation resistance of motor or some other component slipped below the critical 40 meg.
    Mike.

    #356249
    pmb
    Participant

    Re: ZWD16270WI Not Starting

    There is no module in base.
    They wont it done very quickly, So i advised them to call Zanussi, And of course i didnt charge them.

Viewing 8 posts - 1 through 8 (of 8 total)