    hi this model is coming up with e3 the user manual says its a heater fault, ive tested the heater and its ok and there was l/n supply to it and it heated ok, so i left it at that, got called back a couple of days later same fault. so i ran it and it didnt heat up, so i stripped it out and tested everything, all ok again put it on and it heated im assuming it could be the pcb. any ideas welcome. (door loom all ok)

    dw60 sn-71204708 444445899

    many thanks paul

    #358055
    Seamy
    Participant

    Re: newworld dw60 e3

    Most likely its underfilling with water & not able to keep pressure switch for heater closed. Check pressure switch pipes for blockage.

    #358056
    hilly
    Participant

    newworld dw60 e3

    Cheers, checked them all clear I’ve quoted for pcb but he’s on about getting a new one cos he’s not impressed with the quality of this one lol