    Participant

    Morning all , our engineer is at this , 1st fault was not doing full spin , fitted new module tested it all , water going in and fst spin working , now customer called back last night and said not taking in water now.

    checked water fault , heater working ok , water is turned on
    spins and drains ok , even refitted old module just to se if would take water in but no joy

    any ideas with it??

    #358248
    electrofix
    Moderator

    Re: AWCT10L – not take water in

    long shot

    had a few of theses machines where the customer switches iff at the socket before turning off the machine causing the computer to scramble

    cure
    press the off button on the machine till light goes out then turn on again to reset computer

    Dave

    #358249
    razor
    Participant

    Re: AWCT10L – not take water in

    cheers Dave , will ask customer to try that