AEG L16830 W/D

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #65153
    spanner51
    Participant

    prod No 91460212201

    When this machine is switched on and start button is pressed the door locks, the green ‘door lock light’ turns red, and the machine does nothing. No error code, no nothing. I tried to access diagnostic mode without successs. Every 30 seconds it seems to ‘pulse’ and bring on the valves and pump for a split second. All wiring seemed OK. as it has a 3 phase motor, no brushes to check. Any help please?

    #359295
    Criscold
    Participant

    Re: AEG L16830 W/D

    Have you checked insulation on dryer elements ?

    #359296
    spanner51
    Participant

    Re: AEG L16830 W/D

    I went back to this machine and the dryer elements were OK, I was getting 70Mohms. I did manage to access the diagnostic mode and got an error code E5C. Which means ‘Inverter Board Defective’ (master voltage too high)

    Not sure how to test master voltage so I quoted for a new inverter board.

    Not a stock item for Connect or Masterpart, but at the AEG eshop it was priced at £155.00. It made a repair cost of over £200.00 which my customer declined.

    Thanks for your reply