I know this is the diverter valve but the fault is the word of the customer. I couldn’t verify it.
Trying to do the test sequence I got to F1 but it wouldn’t start the test.
Could it be the cycling pump at fault also as in the test procedure?
Thanks
Rob
what happens if you just start a wash program? I personally never bother with the test prog, set a glass wash, close the flap and start up.
checked for water in the base? look for slight leak evidence under the diverter valve, only takes a drop of water on the switch in the valve to cause all sorts of issues.
Hi Mark, can’t start a programme as it is now stuck on F1. Tried shutting door with it on and off, holding the prog button, everything I can think of but no change. This is the first Smeg since the old Servis dishwashers were made by them so no previous.
Will check for a water leak.
Rob
check carefully for an earth leak however small, unplug the circ pump motor, see if that frees off the pcb. dito the alt valve. As she reported a E8 first then I would suspect that.