bosch wae24260/gb/01 washer

Viewing 10 posts - 1 through 10 (of 10 total)
  • Author
    Posts
  • #65515
    adv
    Participant

    on wash can here valves letting in water for a split second a few times then starts to wash with hardly any water in it when try drain no pump action pump clear on spin spins but no pump action am thinkin pcb help lads? 😀

    #360834
    Martin
    Participant

    Re: bosch wae24260/gb/01 washer

    I’m thinking pressure switch.

    #360835
    timdowning
    Participant

    Re: bosch wae24260/gb/01 washer

    Are both valves ok?

    #360836
    adv
    Participant

    Re: bosch wae24260/gb/01 washer

    the valves open for a split second then stop every say 5 secs on fill also no pump action it just sounds like a dodgy pcb a think lol . would preesure switch chock cause this i wonder , pcb 180 quid mmmm

    #360837
    Martin
    Participant

    Re: bosch wae24260/gb/01 washer

    adv wrote:would preesure switch chock cause this i wonder , pcb 180 quid mmmm

    I certainly suggested in my previous post that the fault was more likely to be associated to the pressure switch (PartNo: 428683 – costs just 10 quid by the way!!!!)…..but not in as many words perhaps. I hope that now helps you further in your investigations…..

    God speed……!!!

    Do please keep us informed. 8)

    #360838
    adv
    Participant

    Re: bosch wae24260/gb/01 washer

    ok thanks all check it out ta

    #360839
    adv
    Participant

    Re: bosch wae24260/gb/01 washer

    or maybe a chocked pressure bulb?

    #360840
    Martin
    Participant

    Re: bosch wae24260/gb/01 washer

    Take a butchers at that too while your there. 💡

    #360841
    Micky 32
    Participant

    Re: bosch wae24260/gb/01 washer

    Would a pressure switch cause no pump action though? I’m sure you checked the pump to see if it’s open circuit? I’m sure i came across one of these that when the pump was gone it wouldn’t fill either.

    #360842
    adv
    Participant

    Re: bosch wae24260/gb/01 washer

    thats wat a was thinkin havent tested pump yet was the valves opening as if pcb was dodgy that thoght pcb was suspect had that on few diplomat washers mmm

Viewing 10 posts - 1 through 10 (of 10 total)