refrigeration rig

Home Forums General Trade Forum refrigeration rig

Viewing 11 posts - 1 through 11 (of 11 total)
  • Author
    Posts
  • #65542
    funkyboogy
    Participant

    is their a simple system out that does r600a only

    im looking for something a bit less cumbersome than current vulcan set.

    cheers ally

    #360920
    admin
    Keymaster

    refrigeration rig

    Yes. Simple vac pump and a set of gauges is all you need.

    Bryan

    #360921
    raw
    Blocked

    Re: refrigeration rig

    What Gauges you use bryan for r600a?

    #360922
    admin
    Keymaster

    refrigeration rig

    Just one set of -1 bar. Goes from atmosphere down to minus 1 atmosphere. Then recharge to minus .450 . Perfect charge every time without scales. Never had a recall or failure.

    Bryan

    #360923
    raw
    Blocked

    Re: refrigeration rig

    and where do one find such gauges or make of such ones

    #360924
    Allsorts
    Participant

    Re: refrigeration rig

    and at what cost please?

    George

    #360925
    admin
    Keymaster

    refrigeration rig

    Cost of gauge.. About £25 just replaces one of your gauges display which is obsolete now anyways.part number I will get tomorrow.

    #360926
    raw
    Blocked

    Re: refrigeration rig

    If fridge is low on gas do you just top it up or remove all change drier and refill, do u braze or lokring joints, if braze do u blast it with nitrogen 1st

    #360927
    admin
    Keymaster

    Re: refrigeration rig

    Hi

    If the appliance is low on refrigerant then its got a leak.Line taps I just simply do not like as they can leak and due vibration mixed with r600a.

    I always braze,have done for the past 15 odd years. Treat r600a with respect as any other refrigerant and your fine.R134a isn’t really flammable but it can make you unconscious if burnt during brazing and the lung damage is done.

    Nitrogen, yes I do have a portable kit.How many times a year do i use it..maybe one or two for really stubborn blockages on the old systems.

    Turn up on the February meeting as we are hoping to have it shown using lock ring as well as brazing.

    Bryan

    #360928
    funkyboogy
    Participant

    Re: refrigeration rig

    cheers bryan ..

    let me know gauge part no etc , maybe refrigeration session should be separate session for anyone interested as hands on would be good …
    steady i meant hands on tools ,
    eh maybe not tools hands on equipment,

    ahhhh you know what i mean ….

    #360929
    raw
    Blocked

    Re: refrigeration rig

    if u do day training would come to luton to gain more experience on r600a etc let me know

Viewing 11 posts - 1 through 11 (of 11 total)
  • You must be logged in to reply to this topic.