    Hello, All,

    My folks have a Creda ‘Reversair’ (model no.37742) which recently began tripping the MCB after around 20 minutes use.

    On opening the back, I’ve found the interference suppressor has popped, leaving some waxy residue spattered on the backplate!

    I see that universal suppressors are available to buy in the on-line shop (part no. 1701572), but before I buy a replacement I thought I should check that I’m replacing the right part (i.e. would a blown suppressor cause the MCB to trip?).

    Motor and heating elements seem to be working fine.

    Many thanks,

    SP

    #362519
    iadom
    Moderator

    Re: Interference Suppressor question

    Correct mains filter for that machine is part No: C00206306, which is the Indesit number for a 1701572, 8) and yes it would pop the RCD.

    #362520
    scott_polglase
    Participant

    Re: Interference Suppressor question

    Thanks very much for your confirmation, iadom. Spare part ordered and on its way!