Zanussi ZWD12270S

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #66048
    gadgetdad
    Participant

    Hi guys, yet another pesky Zanussi washer dryer with no heat on the drying cycle.

    I have no voltage at the drying element – have continuity on the resettable cut out and the ntc in the condenser hose and everywhere else I have checked – continuity but no voltage on any of the devices – fan motor runs etc.

    Help !!

    Gadgetdad

    #362851

    Re: Zanussi ZWD12270S

    Are you measuring continuity through condenser hose ntc from board? It’s the wires to it that often break, could be intermittent break, too.
    Mike.

Viewing 2 posts - 1 through 2 (of 2 total)