Bosch wfo2467gb/17

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #66054
    tash
    Participant

    hi been to the above Bosch washer aborts to 1 min.. tried it on rinse and it fills way too high so checked for blockages all ok tried pressure sw on another Bosch works ok.. is it a timed fill on rinse or am I missing something really obvious .. thanks

    #362862

    Re: Bosch wfo2467gb/17

    Seem to remember the 1 min being heater related. May be low ins. or bad terminal.
    Mike.

    #362863
    tash
    Participant

    Re: Bosch wfo2467gb/17

    ok thanks.. but would that make it overfill?

    #362864

    Re: Bosch wfo2467gb/17

    It doesn’t seem logical but I often find fixing the cause of one symptom magically rectifies another or makes the other simpler to find.
    Mike.

    #362865
    tash
    Participant

    Re: Bosch wfo2467gb/17

    heater was ok .. sussed it now pcb giving supply to valve even when p switch signalled correct level.. was constant before but now on off 2 sec intervals.. thanks anyway mike

Viewing 5 posts - 1 through 5 (of 5 total)