November 24, 2011 at 5:41 pm #66469
mikehha
ParticipantTo all hpt engineers (help) I have a m/c that the reduce crease light comes on and flashes but not all the time also you can`t cancel the program and it wont turn off with the on off button so I`m gussing its front panel card rather than the bottom module any suggestions please. mike
November 24, 2011 at 5:49 pm #364233iadom
ModeratorRe: hotpoint wf326
A couple of suggestions, always give the lights by number from top to bottom, left to right etc, functions change but the number as an error code doesn’t.
Assuming that your flashing light is light 2 then suggestion number 2 is to check the Known Error codes thread.
This reveals that light 2 flashing is F04, pressure switch stuck on empty.
it could be a duff pressure switch, gunged up pressure chamber or faulty PCB for starters.
Unlikely to be console module.
November 24, 2011 at 6:04 pm #364234mikehha
ParticipantRe: hotpoint wf326
thanks for that . but I allready new that the second light down ment f04 and have discounted the pressure switch.and there is no blockage.
November 24, 2011 at 6:41 pm #364235iadom
ModeratorRe: hotpoint wf326
mikehha wrote:thanks for that . but I allready new that the second light down ment f04 and have discounted the pressure switch.and there is no blockage.
Always a good idea to include this information in your initial post. 😉
Why have you ruled out the pressure switch, they are prone to failure, sometimes intermittant.
Still don,t think it is the console pcb, unless one of the buttons is stuck in a little.
If all else fails there is EMW to fall back on.
November 24, 2011 at 7:37 pm #364236mikehha
ParticipantRe: hotpoint wf326
Would the pressure switch cause the cancel and the on/off buttons to stop working then.also I suppose I should have mentioned
that the lower module has been changed but it was doing the same with the previous module.November 24, 2011 at 8:34 pm #364237iadom
ModeratorRe: hotpoint wf326
mikehha wrote: also I suppose I should have mentioned
Its best to mention everything that has been tried to date, it saves people asking if you have tried this or that or the other. 😀
In most cases when the machine goes into error it will not switch off or cancel, you have to unplug first.
Personally I would have swapped out the pressure switch first. Also this machine has the sealed drum so darned difficult to get at or clear the pressure chamber. 😥
November 24, 2011 at 10:53 pm #364238mikehha
ParticipantRe: hotpoint wf326
one of the nice things of having a wife as a nurse is that she can find all sorts of things that bend and can clear pressure chambers !!!!!
November 24, 2011 at 11:50 pm #364239iadom
ModeratorRe: hotpoint wf326
mikehha wrote: a nurse can find all sorts of things that bend
That really is an “OOOHH Matron” moment.
November 26, 2011 at 3:22 pm #364240leavemetogetonwithit
ParticipantRe: hotpoint wf326
mikehha wrote:can`t cancel the program and it wont turn off with the on off button
I thought that was a pointer to the 680uf.
Or does it have to have all lights flashing for it to be that?
Mike. -