Hoover HP6 120M overfill??

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #66538
    iadom
    Moderator

    31000497-05511513.

    Initial complaint was of poor/no spin with occasional water left in drum.

    Drain pump is perfect, no blockages of any kind, empties fine.

    Set it to wash and soon noticed it was filling way too high, simple thinks I, blocked pressure chamber or hose.

    Pressure chamber is spotless and pressure hose is clear and undamaged.

    I reset to wash and it filled to within three inches of the top of the door.

    I am going to replace the pressure switch, just wondered if anyone had had a serious overfill on these when the pressure chamber and hose where both OK?

    Jim.

    #364474
    suedehead1
    Participant

    Re: Hoover HP6 120M overfill??

    i have replaced a couple of pressure switches for the same fault.

    #364475
    iadom
    Moderator

    Re: Hoover HP6 120M overfill??

    Thanks, will let you know how I get on. 🙂

    Jim.

    #364476
    iadom
    Moderator

    Re: Hoover HP6 120M overfill??

    sadly pressure switch did not sort it, suspect triac for fill valve at fault, it was filling on every setting as soon as it was switched on, even before the door locked.

    Customer not prepared to spend on it. 😥

    #364477
    Martin
    Participant

    Re: Hoover HP6 120M overfill??

    TR3 triac Jim, easily replaced (or recon board from EMW). But replace the valve too while you’re there!