Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Schrieber / Servis / hygena / Diplomat – F/F help needed.
- This topic has 4 replies, 2 voices, and was last updated 14 years, 4 months ago by
neon_3SP_glow.
-
AuthorPosts
-
December 6, 2011 at 4:18 pm #66705
neon_3SP_glow
ParticipantSchrieber Integrated F/F
APM6855 (038103003)
Firstly I visited the machine to find the motor fan open circuit, this was replaced. The machine was defrosted in the process.Two months later the customer phones again complaining of the same problem (fridge not cooling – freezer is fine). This time the fridge is running the fan (constantly), but the cooling radiator was blocked with ice.
I pressume that I missed this side of the fault on my first visit, it seems the constant running of the fan caused it to ‘burn out’.
I have gained access to the terminal board, This is where i need help…
I have Ohms readings for the two sensors at room temperature (one white sensor, one brown sensor), the two thermo-fuses (little black rectangles) and the defrost heaters, they are as follows:
Brown sensor – 4.03k Ohms
White sensor – 4.24k Ohms
Both of the thermo fuses have virtually no resistance- 0.01 Ohms
Defrost heaters – 0.316k OhmsPlease can someone advise me as to whether these measurments are acceptable or faulty. My instict tells me it is the PCB not turning the defrost heaters on.
Customers is getting irrate!!!
Sorry for the walll of txt – many thanks for reading – Daniel
December 14, 2011 at 10:51 am #364946neon_3SP_glow
ParticipantRe: Schrieber / Servis / hygena / Diplomat – F/F help need
nobody loves me!!!
I’m guessing faulty PCB, But if somebody could advise me of the correct Ohms readings for the defrost heaters that would be ace!
January 18, 2012 at 10:53 am #364947neon_3SP_glow
ParticipantRe: Schrieber / Servis / hygena / Diplomat – F/F help need
bump!/
January 18, 2012 at 8:55 pm #364948SAMURI
ParticipantRe: Schrieber / Servis / hygena / Diplomat – F/F help need
The fault will be the freezer evapoator sensor ( white sensor )
You will need a new sensor.
available from the UK WTA SHOP or AWS.
Bob
February 23, 2012 at 12:11 pm #364949neon_3SP_glow
ParticipantRe: Schrieber / Servis / hygena / Diplomat – F/F help need
Thanks Bob, can i ask how you have come to this cobnclusion? I can get no info on what these sensors should be reading (ohms) when they are not faulty 🙁
Thanks.
-