siemens dryer, cuts out

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #67276
    pmb
    Participant

    Siemens WT46E386gb/02 condenser Dryer
    Was stopping, thought it was pump flout assembly but its not.
    I have it in workshop,Started to cut out,
    Now it stops after a few minutes and flicks on and on and off including display for about a second and i can hear click from PCB i assume is the relay,PCB is over £200.
    Can anything else cause relay to cut out on PCB,

    #366919
    Martin
    Participant

    Re: siemens dryer, cuts out

    Whip the board out and take a close look at those relay pins, I would. 😉

    #366920
    pmb
    Participant

    Re: siemens dryer, cuts out

    Checked board, cannot see anything.
    I dont wont to right it off, then find it was something simple,
    Anyone come across this problem

    #366921
    Martin
    Participant

    Re: siemens dryer, cuts out

    Everything points to the board or connections too or from it. If the machine was ever exposed to damp at any point then chances are there’s verdigre on the contacts or a capacitor is discharging or a relay pitted and not staying engaged. I’m convinced the board is the issue and unless it can be repaired I would scrap it at this point…!!! 🙁

    #366922
    DDDave
    Participant

    Re: siemens dryer, cuts out

    I had the same proble, turned out to be the transformer on the board cutting out. Machine scrapped.