SIXL145 aborts programme

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #68125
    neilbow
    Participant

    customer says they had a power cut, when the power came on the machine restarted, then and I quote the customer it went “squiffy”. Now if you set a programme it takes in water stops empty’s the water and the 12 0’clock position blue LED on the display flashes and the door lock light flashes. Anybody any idea what it is complaining about. I wonder if the module got spiked ?

    Regards
    Neil

    #369943
    iadom
    Moderator

    Re: SIXL145 aborts programme

    F01 = motor triac faulty.

    Check for continuity of motor (Field coil pins 3-5 and
    armature pins 1-2);
    – Check efficiency of module connector block J9, motor
    terminal block and wiring between motor and edge
    connector J9.

Viewing 2 posts - 1 through 2 (of 2 total)
  • You must be logged in to reply to this topic.