    folleyball
    Participant

    Went to this machine yesterday. Its tripped the electrics a couple of times after about 40 minutes into a programme.
    It was failing on the pac tester.
    When I disconnected the mains filter it still failed.
    I’ve ordered a new mains filter. But can somebody tell me why it trips the electrics 40 minutes into the programme. Usually with mains filters it trips almost straight away.

    #372218
    Martin
    Participant

    Re: Hotpoint AQXXL129P1

    Motor, heater or wiring harness touching cabinet probs? Have you checked these items individually or just plugged in via a PAT?

    #372219
    jimca007
    Participant

    Re: Hotpoint AQXXL129P1

    would be inclined to think its a hot heater with the internal wire either warping due to being hot and arcing to the outer case or the heaters got a leak causing the chalk insulator to get damp and eventually short out.

    #372220
    BobHope
    Participant

    Re: Hotpoint AQXXL129P1

    had quite a few of these with that problem every one was the moulded plug arcing internaly, cut of the plug rewired a new one and never had a recall.

    Bob.