AEG L11842 VIT washer dryer

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #68792
    RickT
    Participant

    Hi, This one is causing some grief. Diagnostics bring up E66. Have checked heater ok, but changed anyway. Result E66. Checked circuit from dryer board down to heater ok. Changed the dryer board as per ‘diagnostics instructions’. Result E66. Stripped out main pcb for visuals. No apparant relay dry-joints. Wondering if anyone has come across this ❓

    #372768
    Martin
    Participant

    Re: AEG L11842 VIT washer dryer

    You’ve concentrated your efforts on the dryer heater and the dryer board but have you checked the water heater?

    #372769
    RickT
    Participant

    Re: AEG L11842 VIT washer dryer

    I’ve checked and replaced wash heater. Checked circuit from ‘dryer’ small board down to wash heater all ok but still e66

    #372770
    Martin
    Participant

    Re: AEG L11842 VIT washer dryer

    Oh bugger! Now I’m stuck on this TBH…..The slightest current leakage to earth will show this error code up and I’m sure you’re using a megger to test anyway aren’t you? But all the same, if you were to temporarily disconnect the main earth terminal from the terminal block then try it again…..I wonder if the error would clear? 😕

    #372771
    RickT
    Participant

    Re: AEG L11842 VIT washer dryer

    Yes, all meggered but I will try disconnecting earth. Customer on Easter break so may not be able to get back to her until she returns. Any chance it may be the mainsboard?