    folleyball
    Participant

    The pump is working fine.
    The water is draining out no problem.
    But the machine never gets up to a full spin.
    After 5 mins it flashes F11.

    Is it time to order a board from EMW?

    #372870
    BobHope
    Participant

    Re: Hotpoint WMD960 F11

    F11 is a pump disconnected error, check the wiring and pump for going open circuit before condeming the module.

    Bob.

    #372871
    folleyball
    Participant

    Re: Hotpoint WMD960 F11

    Thanks Bob
    The pump operates fine. Would it be worth trying a different pump first?

    #372872
    BobHope
    Participant

    Re: Hotpoint WMD960 F11

    the pump may be cutting out on the over temp protection just hang a pump on the outside for a quick check.

    Bob.

    #372873
    folleyball
    Participant

    Re: Hotpoint WMD960 F11

    Will try that

    Thanks Bob