    alro
    Participant

    Hi gents
    hfa29k fridge is too cold setting 1 and bit has anyone got tech to help me or the fridge sensor readings at different temps in fridge, as when it switches off it take that long to come back on, customer says is soft scoop icecream is not right and if he turns up to 2or3 his milk is tooo cold, did regas this aweek ago as no ice all over fridge back wall so warm fridge and comp always running put now ice all on fridge rear wall
    cheers alro

    #373137
    dcroome
    Participant

    Hoover HFA29K fridge too cold

    The fridge sensor is foamed in so would be pig of job to cut out insulation . Common for sensor to come away from back wall therefore freezing in fridge.
    In my opinion better of selling new 1 rather than wasting anymore time on this 1

    #373138
    alro
    Participant

    Re: Hoover HFA29K fridge too cold

    Any tech imfo would help please
    cheers alro

    #373139
    SAMURI
    Participant

    Re: Hoover HFA29K fridge too cold

    If you turn the control knob to zero and the fridge continues to run the pcb will be faulty.

    If the fridge cuts out on zero the the sensor will be the fault.

    The sensor is foamed in and is not advisable to replace it as you have to re-insulate the back of the fridge and even if you do a good job any air leak will lead to ice building up on the outside of the fridge.

    Bob

Viewing 4 posts - 1 through 4 (of 4 total)