Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #68940
    dealdd
    Participant

    been out to this d/w and it keeps coming up f14. the circ pump comes on briefly then cuts straight off again, sound like relay is not holding. i have checked for blockages and measured windings one measures 55ohm the other 67ohm. can anyone help??

    #373227
    Seamy
    Participant

    Re: miele d/w g1470

    Likely the circulation pump is not putting up high enough pressuse to activate the heater pressure switch, impellor could be jammed, have a read of the followig technical info on F14..

    The buzzer is activated for 2 minutes. With the circulation pump operating after a water intake step, the heater pressure switch is checked to ensure that sufficient water pressure exists in the wash water circuit. For this the heater relay must have been activated.

    Cause:
    Heater pressure switch B1/13 defective.
    Remedy:
    1. Check the heater pressure switch.
    2. Check the connection plug and wiring harness.
    3. Replace the heater pressure switch, if necessary.

    Cause:
    Circulation pump inoperative. Circulation pressure too low (no pressure at heater pressure switch). Pump may be blocked by foreign objects.
    Remedy:
    1. Check the circulation pump for foreign objects.
    2. Check the circulation pump capacitor.
    3. Replace the circulation pump, if necessary.

    Cause:
    Foreign objects in heater pressure switch.
    Remedy:
    Replace the heater pressure switch.

    Cause:
    Flow meter B3/4 defective (incorrect water quantity registered).
    Remedy:
    1. Check that the plate with the reed switch on flow meter B3/4 is seated correctly.
    2. Check that the reed switch connection plug is seated correctly.
    3. Replace the reed switch, if necessary.
    4. Check the control lead from the electronic to flow meter B3/4.
    5. Remove the water inlet mixer and replace if necessary.

    Cause:
    Circulation pump defective.
    Remedy:
    1. Check the circulation pump power supply.
    2. Check the circulation pump capacitor.
    3. Replace the circulation pump.

    Cause:
    Circulation pump winding overheated; winding protection has cut out.
    Remedy:
    Replace the circulation pump.

    Cause:
    After a water intake step, heater pressure switch B1/13 has not opened switching steps 11–12 and 21–22. This starts the anti-stiction routine.
    Remedy:
    Replace the heater pressure switch.

    Cause:
    Motor capacitor defective.
    Remedy:
    Check the motor capacitor and replace it if necessary.

    Cause:
    Contacts on heater pressure switch B1/13 short-circuited. Contamination on the plug of the heater wiring harness and a conductive connection between the plugs and the main harness causes a short circuit to the contacts.
    Remedy:
    1. Replace the heater wiring harness.
    2. Replace heater pressure switch B1/13.
    3. Reconnect the two individual plugs from the main harness AMP 6.3 x 0.8 and apply new insulation sleeves. Do not interchange the plugs.