aeg 16810 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › aeg 16810 This topic has 1 reply, 2 voices, and was last updated 13 years, 11 months ago by eng14. Viewing 2 posts - 1 through 2 (of 2 total) Author Posts May 2, 2012 at 2:24 pm #69265 eng14Participant hi all went to this w/d and the chamber was totally blocked,cleaned all the crud out but fault still occurs.it runs for 10 minutes they goes back to zero,ideas,wash side fine but this is on dry,richard, 😕 May 2, 2012 at 3:44 pm #374184 MartinParticipant aeg 16810 Probably the dryer NTC wires have broken? Check the NTC (bottom of the condenser matrix) 😉 Another possibility is a duff inlet valve coil (dryer side) ? Sent from my iPad using Tapatalk HD Author Posts Viewing 2 posts - 1 through 2 (of 2 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In